Earthing Arrangements Explained (TN-S, TN-C-S, TT)
Earthing arrangements (TN-S, TN-C-S/PME and TT) define how an installation connects to earth — central to shock protection and correct disconnection under BS 7671.
The earthing arrangement describes how an installation is connected to earth. It is fundamental to protection against electric shock, because it determines how quickly the supply will disconnect if a fault occurs.
The main systems
- TN-S — the supply provides a separate earth conductor all the way back to the source. A traditional arrangement, often with a cable sheath earth.
- TN-C-S (PME) — Protective Multiple Earthing: the earth is derived from the supply neutral at the origin. Common in modern UK supplies, but with specific requirements (and limitations for some uses, such as certain EV charging installations).
- TT — no earth is provided by the supplier; the installation uses its own earth electrode. Common in rural areas, and it relies heavily on RCD protection for safety.
Why it matters on an EICR
The inspector confirms the earthing arrangement is correctly identified, adequate and safe, that the earthing conductor is properly sized, and that disconnection times can be met. Problems here often attract a C2, because they matter under fault conditions.
Related considerations
Earthing works hand in hand with protective bonding and RCD protection. It is also central to EV charging earthing considerations, where open-PEN faults on PME supplies need specific mitigation.
Related service
Earthing & Bonding
Rectification and improvement of earthing and protective bonding arrangements.
Learn moreMore in this topic
Standard explained
AFDDs (Arc Fault Detection Devices) Explained
An AFDD detects dangerous arcing faults in wiring — a common cause of electrical fires — and disconnects the circuit. BS 7671 recommends them for certain premises.
Learn moreKnowledge article
BS 7671 Explained: The Wiring Regulations
BS 7671 — the IET Wiring Regulations — is the national standard for the safety of electrical installations in the UK, currently the 18th Edition.
Learn moreStandard explained
Cable Selection and Sizing Explained
Cable selection under BS 7671 balances current-carrying capacity, installation method, grouping, ambient temperature and voltage drop so conductors run safely.
Learn moreStandard explained
Distribution Boards and Consumer Units Explained
Distribution boards (and domestic consumer units) house the protective devices that control and protect each circuit — their condition is central to any EICR.
Learn moreThis article provides general guidance and distinguishes legislation, British Standards and good practice. It is not legal advice. Always confirm the specific duties applying to your property and tenure.