How Often Is an EICR Required?

Written by Regis ComplianceTechnically reviewed by NAPIT-registered competent personLast reviewed June 2026

How often an EICR is required depends on the type of premises and its use — from every 5 years for rented homes to risk-based intervals commercially.

How often an EICR is required depends on the type of premises, how it is used, and the environment it operates in. There is no single figure that applies everywhere — the maximum interval is a starting point that a competent person can shorten based on the condition and risk of the installation.

Common maximum intervals

BS 7671 and IET guidance set recommended maximum periods between inspections. Widely used benchmarks include:

  • Rented homes (England): at least every 5 years — a legal requirement under the 2020 Regulations.
  • Owner-occupied homes: recommended at least every 10 years, or on change of occupancy.
  • Commercial and industrial premises: commonly 5 years, subject to risk assessment.
  • Higher-risk environments (for example swimming pools, construction sites, agricultural premises): shorter intervals, sometimes 1–3 years.

Why the interval can be shorter

The competent person completing an EICR records a recommended date for the next inspection. This may be earlier than the maximum where:

  • the installation is older or shows signs of deterioration;
  • the premises has heavy use, harsh conditions, or a history of faults;
  • there has been a change of use or occupancy; or
  • the installation has been altered or extended.

Change of occupancy and events

An EICR is also good practice — and sometimes required — at particular points:

  • Change of tenant or owner for rented and sold property.
  • After significant alteration to the installation.
  • Following a suspected fault, fire, or flood affecting the electrics.

Keeping evidence

Whatever the interval, duty holders should keep the report and any remedial certificates, and diarise the next due date. A compliance calendar across a portfolio prevents reports lapsing and demonstrates a proactive approach to safety — which is exactly what enforcement bodies expect to see.

Frequently asked questions

How often does a landlord need an EICR?

In England, private landlords must have the fixed installation inspected and tested at least every 5 years, or more often if the previous report specifies a shorter interval.

Does a new installation need an EICR straight away?

No. A brand-new installation is certified with an Electrical Installation Certificate (EIC). The first periodic EICR is due at the interval recommended on that certificate.

This article provides general guidance and distinguishes legislation, British Standards and good practice. It is not legal advice. Always confirm the specific duties applying to your property and tenure.

Speak to a compliance engineer

The quickest way to get started is a quick call. We'll tell you exactly what you need.

We use essential cookies to run this site. With your consent we also use analytics and marketing cookies to improve the site and measure our advertising. See our cookie policy.