BS 5266 Overview: Emergency Lighting Standard
BS 5266 is the UK code of practice for emergency lighting — covering design, installation and maintenance so illumination is provided when the normal supply fails.
BS 5266 is the British Standard code of practice for emergency lighting. It guides the design, installation, commissioning and maintenance of systems that provide illumination automatically when the normal supply fails.
What BS 5266 covers
- Where emergency lighting is needed — escape routes, open areas, high-risk task areas.
- How much light is required and for how long (the rated duration, commonly up to three hours).
- Testing and maintenance regimes to keep the system reliable.
- Documentation — the completion certificate and logbook.
Standard, not law — but it satisfies the law
Like other British Standards, BS 5266 is not itself legislation. However, meeting it is the recognised way to satisfy the duty under the Regulatory Reform (Fire Safety) Order 2005 to provide and maintain appropriate emergency lighting. A fire risk assessment determines the extent required.
Why it matters
Following BS 5266 ensures the system will actually perform when it is needed — the whole point of emergency lighting. For the practical testing regime, see monthly testing and annual duration testing.
Related service
Emergency Lighting Testing
Function and duration testing of emergency lighting to support BS 5266 good practice.
Learn moreMore in this topic
Knowledge article
Emergency Lighting Annual Duration Testing
The annual emergency lighting test discharges the batteries for their full rated duration (commonly 3 hours) to confirm the system lasts the required period.
Learn moreKnowledge article
Common Emergency Lighting Defects
Common emergency lighting defects include failed batteries, faulty luminaires, missing coverage, no logbook and fittings that light up but fail the duration test.
Learn moreKnowledge article
Emergency Lighting Explained
Emergency lighting provides illumination automatically when the normal supply fails, helping people evacuate safely — governed by BS 5266.
Learn moreKnowledge article
Escape Route Lighting Explained
Escape route lighting illuminates corridors, stairways and exits when the supply fails, so occupants can identify and use escape routes safely under BS 5266.
Learn moreThis article provides general guidance and distinguishes legislation, British Standards and good practice. It is not legal advice. Always confirm the specific duties applying to your property and tenure.